29. Select the correct device type (e.g. H8/36079F for RSKH836079).
30. Select “Erase Flash and Connect”.
31. Select “Power target from Emulator” and select “5V” if the E8A is to provide the
power to the RSK board. Otherwise connect a 5V centre positive power supply.
32. Click <OK>.
33. The first time the E8A is used the ‘E8AH8’ dialog appears:
Otherwise skip to step 37.
34. Click <OK>.
35. Select “Renesas E-Series USB Driver”. Select “USB interface”. The channel number will not be needed.
36. Click <Close>.
37. Accept any dialog warning that a different version of E8A firmware is necessary to work with the application.
Allow download of firmware to complete, this may take several seconds.
38. Select the ID Code (“0E8A” for the RSKH836079) then click <OK>. The flash memory write program and E8A monitor are then
downloaded to the microcontroller
39. Right click on the download module listed in the left hand pane and select ‘Download’.
The code will be downloaded to the microcontroller. This may take several seconds.
40. Click the <Reset – Go> button.
The code will run and you will see the LEDs flash on the board.
41. Click the <Stop> button.
The code will stop and the source code will be opened at the current program counter.
5. Next Step
After you have completed this quick start procedure, please review the tutorial code and sample code that came with the kit. You can add projects to the current
workspace by selecting (Project > Insert Project) from the main menu. The tutorials will help you understand the device and development process using Renesas
Development Tools.
The Hardware manual supplied with this RSK is current at the time of publication. Please check for any updates to the device manual from the Renesas internet site at:
6. Renesas H8 Compiler
The version of the compiler provided with this RSK is fully functional but time limited. You have 60 days to evaluate the full product before the compiler will limit the code
linker to 64k bytes. Full licensed H8 compiler versions are available from your Renesas supplier.
7. Support
Technical Contact Details
America:
Europe:
Japan:
Note on Autoupdate: The Autoupdater is configured to automatically add itself to the Startup folder in the Windows Start Menu and use the registry defaults for
access to the web. After restarting the machine the Icon will appear in the System Tray next to the clock. To change the settings or access Autoupdate, simply
right-click on the icon and use the menu that appears.
© Renesas Technology Europe Ltd 2007.
© Renesas Technology Corporation 2007.
D007914_11_S02_V01
|
RCA Projection Television MM27110 User Guide
Roku Portable Multimedia Player 2450D User Guide
Rowenta Iron Precision Steam Iron User Guide
Ryobi Drill SA720 User Guide
Ryobi Saw P530 User Guide
Samsung CRT Television CL29Z7H, CL29Z6H, CL32Z7H, CL32Z6H, CL34Z7H, CL34Z6H User Guide
Samsung Refrigerator RF221NCTABC User Guide
Sanyo Digital Camera VPC AZ1 User Guide
Sears Oven 36725 User Guide
Sears Planer 11320680 User Guide